Your DSC Security System is made up of a DSC control panel, one or more keypads and various sensors and detectors. The control panel, which is a metal cabinet, will be mounted out of the way in a utility closet or in the basement. The metal cabinet contains the system electronics, fuses and back up battery. View and Download DSC SCW9047-433 user manual online. Self Contained Wireless. SCW9047-433 Security System pdf manual download. Also for: Scw9045-433, Scw9047-868, Scw9045-868. Manual & Installation Manual. DSC Power series user guide Keywords: dsc alarm system, dsc power series, home alarm All DSC 433MHz devices the system will keep the zone definitions selected when the (Section 1 (Disclaimer of Warranties Instruction Manual). DSC SCW9047-433 Manual Online: Trouble Conditions, Alarm Memory, Access Code. This site uses cookies to offer you a better browsing experience. By continue to navigate through this site or by clicking Approve, you consent to the use of cookies on your device as described in our.
Advertising
1
About Your Security System
Your Security System has been designed to provide you with the greatest possible flexibility and con-
venience. Read this manual carefully and have your installer instruct you on your system's operation and on which features have been implemented in your system. All users of this system should be equally instructed in its use. Fill out the “System Information” page with all of your zone information and access codes and store this manual in a safe place for future reference.
NOTE: Please consult your installer for further information regarding the false alarm reduction
features built into your system as all are not covered in this manual.
Fire Detection
This equipment is capable of monitoring fire detection devices such as smoke detectors and provid-
ing a warning if a fire condition is detected. Good fire detection depends on having adequate num- ber of detectors placed in appropriate locations. This equipment should be installed in accordance with NFPA 72 (N.F.P.A., Battery march Park, Quince MA 02269). Carefully review the Family Escape Planning guidelines in this manual.
NOTE: Your installer must enable the fire detection portion of this equipment before it becomes
functional. Dsc Power Series 433 Keypad Manual
Testing
To ensure that your system continues to function as intended, you must test your system weekly.
Please refer to the “Testing your System” section in this manual. If your system does not function properly, call your installing company for service.
Monitoring
This system is capable of transmitting alarms, troubles & emergency information to a central station. If you
initiate an alarm by mistake, immediately call the central station to prevent an unnecessary response.
NOTE: The monitoring function must be enabled by the installer before it becomes functional.
NOTE: This system has a communicator delay of 30 seconds. It can be removed, or it can be Dsc Power Series 433 User Manual
increased up to 45 seconds by the installer.
NOTE: Ensure that your Installer verifies that your system is compatible with the Central Station
Receiver format at yearly intervals.
Maintenance
With normal use, the system requires minimum maintenance. Note the following points:
• Do not wash the security equipment with a wet cloth. Light dusting with a slightly moistened cloth
should remove normal accumulations of dust.
• DSC recommends replacing the standby batteries every 4-5 years.
• For other system devices such as smoke detectors, motion detectors, glassbreak detectors or door/
window contacts, consult the manufacturer’s literature for testing and maintenance instructions if
applicable.
General System Operation
Your security system comprises an integrated alarm control/keypad and various sensors and detec-
tors. The system is mounted by the main exit/entry location. The system is self-contained; electronics and standby battery are housed within the keypad unit.
NOTE: Only the installer or service professional should have access to the system.
The security system has several zones of area protection. Each of these zones communicates to a sin-
gle wireless sensor (motion detectors, glassbreak detectors, door contacts, etc.) or to one or more hard wired sensors. A sensor in alarm is indicated by messages on the LCD keypad. Additional features include: Automatic Inhibit (Swinger Shutdown) for Alarm; Tamper and Trouble signals after 3 occurrences in a given set period; and a Programmable Keypad Lockout option.
NOTE: For SIA CP-01 classified installations, the swinger shutdown feature is programmed such
that one or two trips will shut down the zone. The zone will be restored after a manual reset (by entering the access code at the time of disarming the alarm system) or it will be reset automatically after 48 hrs with no trips on any zones.
Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
Advertising
PC1616/PC1832/PC1864 STANDARD INSTALLATION GUIDE
This Installation Guide provides the basic installation, wiring and programming information required to program the PowerSeries PC1616,
PC1832 and PC1864 control panels.
This guide shall be used in conjunction with the PowerSeries PC1616/1832/1864 Reference Manual
which can be obtained from your local dealer or downloaded from the DSC web site at www.dsc.com.
NOTE: All necessary information required to meet UL Listing requirements is contained in this document.
Read the complete guide, then work through each step as indicated.
FEATURES
PC1616
PC1832
PC1864
OUT Of THE BOX
On-board Zones
6
8
Dsc 433 Alarm Manual
8 Silverfast se plus 8 download mac.
Qty 1
❑
Qty 1
❑
Qty 1
❑
Qty 1
❑
Qty 2
❑
Qty 1
❑
Qty 4
❑
Qty 16
❑
Qty 1
❑
Qty 1
❑
Qty 1
❑
Qty 1
❑
Cabinet
PC Module Installation guide User manual Cabinet Label Cabinet Door Plug Standoffs 5.6K
2.2K
Ω Resistors
1.0K
Ω Resistors
10
Ω Resistors
Grounding Kit
Hardwired Zones
16 (1xPC5108)
32(3xPC5108)
64 (7xPC5108)
Wireless Zones
16
32
32
Keypad Zone Support
✔
✔
✔
On-board PGM Outputs Fotor 3.0.0 mac download.
PGM 1 - 50mA
PGM 2 - 300mA
PGM 1 - 50mA
PGM 2 - 300mA
PGM 1, 3, 4 - 50mA
PGM 2 - 300mA
PGM Expansion
8x50mA (PC5208)
4x500 mA (PC5204)
8x50mA (PC5208)
4x500 mA (PC5204)
8x50mA (PC5208)
4x500 mA (PC5204)
Keypads
8
8
8
Partitions
2
4
8
SPECIFICATIONS
Temp Range .... 0°C-49°C (32°F-120°F)
Humidity (Max).............. 93%R.H. Power Supply.... 16.5V
AC
/40VA @60Hz
Current Draw (Panel) .....110mA (nom.)
Aux+ Output......11.1-12.6V
DC
/700mA
Bell Output .......11.1-12.6V
DC
/700mA
User Codes
32 + Master Codes
32 + Master Codes
32 + Master Codes
Event Buffer
500 Events
500 Events
500 Events
Transformer Required
16.5V
AC
/40VA
16.5V
AC
/40VA
16.5V
AC
/40VA
Battery Required
4Ah / 7Ah/14AHr
4Ah / 7Ah/14AHr
4Ah / 7Ah/14AHr
Bell Output
12V/700 mA (cont)
12V/700 mA (cont)
12V/700 mA (cont)
COMPATIBLE DEVICES
Keypads (
Backward compatible with all PowerSeries keypads)
Modules
PK5500 Keypad..............................125mA (max.)
PK5501 Keypad..............................125mA (max.) PK5508 LED Keypad..........................125mA (max.) PK5516 LED Keypad..........................125mA (max.) PC5532Z LED Keypad ........................125mA (max.) LCD5511 Fixed Message LCD Keypad............ 85mA (max.) LED5511Z 8-zone LED Keypad .................100mA (max.)
Cabinets
PC5003C ................... 222x298x78mm (11.3x11.7x3.0in)
PC500C ..................... 213x235x78mm (8.4x9.25x3.0in)
Refer to the Reference Manual for alternate control cabinets
T-Link TL-250/TL300 ............................275/350mA
PC5100 2-wire Interface ...... 40mA plus devices to 170mA max. PC5132-433 Wireless Receiver .......................125mA RF5108-433 Wireless Receiver .......................125mA PC5108 Zone Expander .............................30mA PC5204 Power Supply with 4 Programmable Outputs ......30mA PC5208 Low Current Programmable Output Module .......50mA PC5400 Printer/DVAC Module .........................65mA PC5401 Bi-Directional RS232 Module (Not UL Listed) ......65mA Escort5580 Telephone Interface Module ................130mA
Refer to the Reference Manual for additional devices.
Classified in Accordance with ANSI/SIA CP-01-2000 (SIA-FAR)
2 9 0 0 7 1 0 9 R0 0 3